Landlord Winter Compliance Checklist: CP12 Gas Safety & EICR Testing Explained

Winter puts more pressure on rental properties than any other time of year. Boilers work harder, tenants spend more time at home, and small faults quickly turn into urgent callouts. It is also when gaps in safety paperwork are most likely to come to light, often after a breakdown or a complaint.
How much does an eicr cost cover image

Winter puts more pressure on rental properties than any other time of year. Boilers work harder, tenants spend more time at home, and small faults quickly turn into urgent callouts. It is also when gaps in safety paperwork are most likely to come to light, often after a breakdown or a complaint.

For landlords in England, two certificates sit at the heart of property safety: the annual gas safety record (often called a CP12) and the Electrical Installation Condition Report (EICR). In this guide, the team at Newton Electrical and Mechanical explains what each one involves, the deadlines you need to meet and a simple checklist to get your properties ready for winter.

This guide covers the rules for privately rented homes in England. It is general guidance, not legal advice. Always check the latest requirements on GOV.UK or with your letting agent.

CP12 Gas Safety Checks Explained

Under the Gas Safety (Installation and Use) Regulations 1998, landlords must make sure every gas appliance, fitting and flue they provide is safe. That means an annual gas safety check by a Gas Safe registered engineer.

What the Check Covers

  • Testing gas appliances such as boilers, gas fires and cookers for safe operation.
  • Checking flues and chimneys are clear and working correctly.
  • Confirming there is enough ventilation for each appliance.
  • Tightness testing the gas installation for leaks.
  • Checking burner pressure and gas rate against the manufacturer’s settings.

Key Deadlines

  • Every 12 months: Each appliance and flue must be checked at least once a year.
  • Within 28 days: Existing tenants must receive a copy of the gas safety record within 28 days of the check.
  • Before move-in: New tenants must receive a copy before they move in.
  • Keep for 2 years: Records must be kept for at least two years.

Checks can be carried out up to two months before the due date while keeping the original expiry date. This makes it easier to plan inspections without losing time on the certificate.

A Gas Safety Check Is Not a Service

A gas safety check confirms appliances are safe. A boiler service goes further, cleaning and tuning the boiler so it runs efficiently and reliably. Many landlords book both together in autumn to reduce the risk of winter breakdowns.

EICR Testing Explained

The Electrical Safety Standards in the Private Rented Sector (England) Regulations 2020 require landlords to have the fixed electrical installation inspected and tested by a qualified person. The result is an Electrical Installation Condition Report (EICR).

What the Inspection Covers

  • The consumer unit (fuse board) and circuit protection, including RCDs.
  • Wiring, sockets, switches and light fittings.
  • Earthing and bonding.
  • Signs of damage, wear, overheating or unsafe DIY alterations.

Understanding EICR Codes

CodeMeaningAction needed
C1Danger present, risk of injuryImmediate remedial work
C2Potentially dangerousRemedial work required
FIFurther investigation neededInvestigate without delay
C3Improvement recommendedAdvisory, not a fail

Any C1, C2 or FI result means the report is unsatisfactory and work must be done.

Key Deadlines

  • At least every 5 years: Or sooner if the previous report recommends it.
  • Within 28 days: Give existing tenants a copy of the report within 28 days of the inspection.
  • Before move-in: Give new tenants a copy before they occupy the property.
  • Within 7 days: Provide a copy to the local council if they request it.
  • Within 28 days for repairs: Complete remedial work within 28 days, or sooner if the report says so, then give written confirmation to the tenant and the council.

Councils can issue financial penalties of up to £30,000 for breaches of these regulations.

Your Landlord Winter Compliance Checklist

Work through this list for each property before the coldest months arrive.

Certificates and Paperwork

  1. Check your gas safety record dates. Book the next CP12 if it falls due over winter, using the two-month early window.
  2. Check your EICR date. Confirm the current report is less than five years old and that any remedial work has been completed and confirmed in writing.
  3. Issue copies to tenants. Make sure every tenant has the current gas safety record and EICR.
  4. Store records safely. Keep digital copies where you or your agent can find them quickly if the council asks.

Heating and Gas

  1. Book a boiler service. Combine it with the gas safety check to save a visit.
  2. Check the condensate pipe. External condensate pipes can freeze and cause boiler lockouts. Make sure they are insulated or correctly sized.
  3. Bleed and balance radiators. Cold spots lead to tenant complaints and higher bills.
  4. Test heating controls. Make sure thermostats and timers work and tenants know how to use them.

Alarms and Safety

  1. Test smoke alarms. At least one smoke alarm is required on every storey used as living accommodation.
  2. Test carbon monoxide alarms. A CO alarm is required in any room with a fixed combustion appliance, such as a boiler or gas fire (gas cookers are excluded).
  3. Repair faulty alarms promptly. Landlords must repair or replace alarms once they are told they are not working.

Protecting the Property

  1. Lag exposed pipework. Insulate pipes in lofts, garages and external walls to prevent burst pipes.
  2. Plan for empty properties. Keep heating on a frost setting, or drain down the system, in void properties over winter.
  3. Share winter advice with tenants. Explain how to repressurise the boiler, where the stopcock is and who to call in a breakdown.

Frequently Asked Questions

Can the gas safety check and EICR be done on the same day?

Yes, if your contractor covers both gas and electrical work. Booking them together means one access arrangement with your tenants and less disruption.

Do I need an EICR for every rental property?

Most privately rented homes in England are covered, including HMOs. Some tenancy types are exempt, such as lodgers living with the landlord. Check GOV.UK if you are unsure.

What happens if my property fails its EICR?

You must arrange remedial work within 28 days, or sooner if stated, and send written confirmation to your tenant and the council. A qualified electrician can carry out the repairs and confirm the installation is safe.

Who can carry out a gas safety check?

Only a Gas Safe registered engineer. You can check an engineer’s registration and qualifications on the Gas Safe Register website.

Can my letting agent manage this for me?

Yes. Many landlords ask their agent to book inspections. As the landlord, you are still legally responsible for making sure the checks are done.

Book Your Landlord Safety Bundle

Newton Electrical and Mechanical offers combined CP12 gas safety checks and EICR inspections for landlords across Leicester, Hinckley and the wider Midlands. Our Gas Safe registered engineers and NICEIC approved electricians complete both inspections together, with one point of contact and one invoice. If remedial work is needed, you receive a clear, fixed quote and our own team can carry it out.

  • Telephone: 01455 230 114
  • Online: Fill out our website contact form to book your landlord safety bundle.